Details information£º
Model: SFP40S
50Hz |
Continuous power |
36kw(45kva) |
Output voltage |
380/430V |
Standby power |
40kw(50kva) |
Rate Speed |
1500r/min |
¡ñPAYMENT TERM
T/T 30% deposit before production, 70% balance before shipment by T/T.
¡ñLEAD TIME
Prompt shipment against payment;
¡ñCOMMERCIAL TERMS:
Our company reserves the rights to explain any change in specifications.
Technical parameters of Gen-Set:
Power factor |
COS¦µ=0.8£¨lagging£© |
Start mode |
Electric |
Noise level |
60-65db |
Packing dimension |
2600*1100*1500MM£¨L*W*H£© |
Fuel consumption: |
13.5L/H(50Hz), 18L/H(60Hz) |
Weight |
1020Kg |
Rated currency(amps) |
85.5 |
Protection£º |
Low oil-pressure, High water temperature,
Over-speed, Over-current. |
Technical parameters of Engine:
Brand |
Perkins |
|
|
Model |
1004G |
Power |
40KW |
Original: |
China |
Rated Voltage |
380/480V |
Cylinders |
4 |
Cylinders Layout |
Line |
Fuel |
0# light diesel |
Voltage Control |
AVR |
Start mode |
DC24V electric start |
Overload |
110% |
Speed-Governing |
Electric |
Steady Speed Droop |
¡Ü1% |
Technical parameters of Alternator:
Brand£º |
Learnt |
Power |
40kw |
Model£º |
SLW-40 |
Original |
China |
Protection |
IP21 |
Rated voltage |
380/430 V |
Frequency fluctuation |
¡Ü¡À0.5 % |
Frequency regulation |
¡Ü¡À0.5 %£¨stable£© |
Voltage distortion |
£¼4% |
Voltage control |
AVR |
Technical parameters of Control Panel:
Brand |
2001 |
Start or Stop Generator set manually/ Automatically |
Generator over/under frequency protection |
Open controller output can be defined as Pre-heat/Idle output |
Generator over/under/unbalance voltage Protection |
High Coolant temperature protection |
Over speed protection |
Low Oil pressure protection |
Over speed protection |
Over load protection |
Available for remote control |
Note£ºindicate this function depend on the set points of the controller in field
|
1. Accessories.
The standard accessories
Single-bearing generator again drops. IP21. Insulation H
Radiator for 50¡æ ambient temperature and double-deck cooling
The Electric start and 24v charger
Regulator
Standard air filter
Automatic control panel
Storage battery
Switch for out-wire
Steel base-frame against vibration
Soft pipe for fuel and handle for lube going-out
Operation manual
Plastic packing
2. Testing conditions.
Standard Air Intake Temperature 25oC
Air Intake Pressure 100kpa
Standard Light Diesel 0# or 10# Light diesel
Fuel Intake Temperature 40oC
Air Intake Restriction 254mmHg
Exhaust Back Pressure 76mmHg
Lubricant Oil 15W40-CF4 Upgrade
3. Operation.
Continuous power: operate continuously for 24h in a day. 10% overload for
An hour is allowed in a 12 hours.
Standby power: this is used only when the civil power is off. Overload is not allowed.
It is necessary to pay additional if you need these accessories as follows:
ATS (Automatic transfer switch)
ATS is such a system that can exert the function automatically by transferring two circuits to recover power supply while powering off, in stead of manual work.
MCCB (Breaker)
Battery charger
|