Details information£º
Model: SFCD100S
50Hz |
Rate Speed |
1500r/min |
Output voltage |
380/440V |
Model |
Standby power |
Continuous power |
Engine |
Alternator |
KW |
KVA |
KW |
KVA |
SFDCS100K |
100 |
131 |
90 |
119 |
6BTA5.9£G2 |
UCI274D |
Silent with ATS
¡ñQUANTITY
3 SETS;
¡ñPAYMENT TERM
T/T 30% deposit before production, 70% balance before shipment by T/T.
¡ñLEAD TIME
Prompt shipment against payment;
¡ñCOMMERCIAL TERMS:
Our company reserves the rights to explain any change in specifications.
Power factor |
COS¦µ=0.8£¨lagging£© |
Start mode |
Electric |
Noise level |
60-65dB |
Packing dimension |
3350*1150*1650MM£¨L*W*H£© |
Fuel consumption: |
22L/H |
Weight |
2200Kg |
Rated currency(amps) |
152 |
Protection£º |
Low oil-pressure, High water temperature,
Over-speed, Over-current.
|
In-line, 4 Cylinder, 4 Cycle Diesel Engine |
Bore¡ÁStroke |
102mm¡Á120mm |
Displacement |
5.9 Liters |
Compression Ration |
17.0£º1 |
Rated Speed |
1500r/min(1800r/min) |
Rated Power |
110kW(120kW) |
Standby Power |
120kW(130kW) |
Fuel Injection Pump |
A Injection Pump |
Governor |
GAC Electrical Governor |
Steady Speed Droop |
¡Ü1%Electrical Governor |
Lubricant Capacity |
16 Liters |
Coolant Capacity |
14 Liters£¨Engine Only£© |
Net Weight |
425kg |
Wet Weight |
450kg |
Overall Dimension(L¡ÁW¡ÁH) |
996mm¡Á711mm¡Á992mm |
Coolant Intake Size |
¦µ58mm |
Coolant Outlet Size |
¦µ45mm |
Flywheel/Flywheel Housing |
SAE3#/SAE3# or SAE2#/SAE2# |
Cooling Way |
Positive Water Cooling Cycle |
Technical Datasheet
Speed |
1500r/min(50Hz) |
1800r/min(60Hz) |
Output Power |
Engine Output |
Engine Output |
Standby Power |
120kW |
132kW |
Prime Power |
110kW |
120kW |
Test Condition
Standard Air Intake Temperature |
25¡æ |
Air Intake Pressure |
100kPa |
Standard Light Diesel |
0# or ¨C10# Light Diesel |
Fuel Intake Temperature |
40¡æ |
Air Intake Restriction |
251mmHg |
Exhaust Back Pressure |
76mmHg |
Lubricant Oil |
15W40-CF4 Upgrade |
Design Characteristic
Belt drive system : Belt drive system with tensioner offering automatic belt tension.
Maintenance: Both cylinder bore and cylinder head valve guide tube can be repaired by resisting.
Connecting rod: Alloy steel with high strength and inclined cutting.
Crankshaft: Alloy steel with whole bearing supporting and bearing and round corner harden.
Cylinder block: Dragon door style cylinder block without liner and with water pump turbo house resisted.
Fuel system: A fuel injection pump with electrical governor or mechanical governor.
Garret turbocharger: Bypass high efficient turbocharger.
Piston: Silicon- aluminium alloy piston with dual Ni-resist and oil cooling.
Starting function: Be started at -12¡æ without assistant installation; Be started at -35¡æ with assistant installation.
Fuel consumption: Excellent fuel consumption with B.S.F.C 220g/kw.h.
Construction characteristic: Simple and compact construction, fewer components and light weight.
Attachment£¨Power Pickup£©equipment:
Attachment equipment can be offered according to customer¡¯s requirements. For sufficiently unleashing engine performance, whole engine attachments from our company, evaluated by Dongfeng Cummins Engine Company, be recommended.
Brand£º |
Stamford |
Power |
90KW(113KVA) |
Model£º |
UCI274D |
Original |
China |
Protection |
IP23 |
Rated voltage |
380/430 V |
Frequency fluctuation |
¡Ü¡À0.5 % |
Frequency regulation |
¡Ü¡À0.5 %£¨stable£© |
Voltage distortion |
£¼4% |
Voltage control |
AVR |
Technical parameters of Control Panel:
Brand |
UPWIN 2210 |
Start or Stop Generator set manually/ Automatically |
Generator over/under frequency protection |
Open controller output can be defined as Pre-heat/Idle output |
Generator over/under/unbalance voltage Protection |
High Coolant temperature protection |
Over speed protection |
Low Oil pressure protection |
Over speed protection |
Over load protection |
Available for remote control |
Note£ºindicate this function depend on the set points of the controller in field |
1. Accessories.
The standard accessories
Single-bearing generator again drops. IP21. Insulation H
Radiator for 50¡æ ambient temperature and double-deck cooling
The Electric start and 24v charger
Regulator
Standard air filter
Automatic control panel
Storage battery
Switch for out-wire
Steel base-frame against vibration
Soft pipe for fuel and handle for lube going-out
Operation manual
Plastic packing
Flexible coupling joint
2. Testing conditions.
Standard Air Intake Temperature 25oC
Air Intake Pressure 100kpa
Standard Light Diesel 0# or 10# Light diesel
Fuel Intake Temperature 40oC
Air Intake Restriction 254mmHg
Exhaust Back Pressure 76mmHg
Lubricant Oil 15W40-CF4 Upgrade
3. Operation.
Continuous power: operate continuously for 24h in a day. 10% overload for
An hour is allowed in a 12 hours.
Standby power: this is used only when the civil power is off. Overload is not allowed.
It is necessary to pay additional if you need these accessories as follows:
ATS (Automatic transfer switch) Include
ATS is such a system that can exert the function automatically by transferring two circuits to recover power supply while powering off, in stead of manual work.
MCCB (Breaker)
Battery charger
|